Electromagnetic Flow Meter

As a leading  instrument manufacturer and distributor in India, we have more than 12 years of experience in providing the highest quality flow meters to engineers, contractors, manufacturers, distributors and technology companies in various countries.
During the whole sales process, we will timely provide the status of your order, and  comply with the on-time delivery of the product..
Through strict cost control, quality control inspection and five-star quality service, we believe you will get more appropriate water meter solutions.
Your comments are very valuable!If you have any questions or comments, please contact us by email below.

Integrated Electromagnetic Flow Meter :

Nominal diameter: DN3-DN3000
Nominal pressure: 0.6-4.0MPA
Accuracy: ± 0.5% of indicated value
Lining material: polyurethane rubber / chloroprene rubber / polytetrafluoroethylene / silicone lining
Electrode form: standard type / scraper type / replaceable type
Electrode material: 316L / Haz alloy B / Haz alloy C / titanium / tantalum / platinum
Medium temperature: integrated: -20 ℃ ~ + 70 ℃
Ambient temperature: -25 ℃ ~ + 40 ℃
Ambient humidity: 5 ~ 100% RH (relative humidity)
Medium conductivity: ≥20
Measuring range: 1500: 1 flow rate setting <15m / s
Structure: integrated / split / immersed / explosion-proof
Protection level: Exmd || CT4
Product standard: JB / T9248-1999 electromagnetic flowmeter


Split Electromagnetic Flow Meter :

Nominal diameter: DN3-DN3000
Nominal pressure: 0.6-4.0MPA
Accuracy: ± 0.5% of indicated value
Lining material: polyurethane rubber / chloroprene rubber / polytetrafluoroethylene / silicone lining
Electrode form: standard type / scraper type / replaceable type
Electrode material: 316L / Haz alloy B / Haz alloy C / titanium / tantalum / platinum
Medium temperature:
Split type: 1. Polyurethane rubber, neoprene, polytetrafluoroethylene, silicon-fluorine lining
                   2.PTFE lining / PFA lining / F46 lining
Ambient temperature: -25 ℃ ~ + 40 ℃
Ambient humidity: 5 ~ 100% RH (relative humidity)
Medium conductivity: ≥20
Measuring range: 1500: 1 flow rate setting <15m / s
Structure: integrated / split / immersed / explosion-proof
Protection level: Exmd || CT4
Product standard: JB / T9248-1999 electromagnetic flowmeter


Technical performance parameters

Main powerAC220V 50Hz /DC24V/3.6V
Power consumption<15W(Supporting power consumption with sensors)
Display and buttonsDisplay in Chinese and English, can display instantaneous flow, cumulative flow and alarm display (excitation open circuit alarm, empty pipe alarm, flow limit alarm). 4 membrane touch switches for data setting
CounterForward total, reverse total
Output
Analog outputTwo-way two-way, fully isolated 0~10mA/4~20mA
Frequency outputForward and reverse flow output, the upper limit of output frequency can be set within 1 ~ 5000Hz. Open collector bidirectional output of transistor with photoelectric isolation. External power supply is not greater than 35V, the maximum current of the collector when conducting is 50mA
Alarm OutputTwo open-collector alarm outputs with photoelectric isolation transistors. The external power supply is not greater than 35V, and the maximum current of the collector when it is turned on is 250mA. Alarm status: fluid empty pipe, excitation disconnection, flow overrun.
Pulse outputForward and reverse flow output, the upper limit of output pulse can reach 5000CP / S. The pulse equivalent is 0.0001 ~ 1.0m³ / P. The pulse width is automatically set to 20ms or square wave. Open collector output of transistor with photoelectric isolation. External power supply is not greater than 35V, the maximum current of the collector when conducting is 50mA
Matching accuracy± 0.5% of market value, optional ± 0.2% or 1% of indicated value
Damping time constantContinuous variable from 0 ~ 100s (90%) time grading optional
communicationOptional RS232C or RS485 serial communication interface, HART communication protocol, with anti-lightning protection
Loss of powerThe internal design of the instrument has a power-off clock, which can store 16 drop-out records (10 years)
Protection levelIP65
Explosion-proof markExs[ia]ia||cT5

Lining material

MaterialMain performance
Polyurethane rubber1. Very good wear resistance coal slurry, mud, ore slurry, etc.
2. Not resistant to acid, alkaline and other corrosive or high temperature media
3. There must be no negative pressure in the pipeline
Neoprene1. Very good elasticity and wear resistance
2. Capable of measuring domestic sewage, non-corrosive industrial sewage PH value: in the range of 6/7/8, temperature below 80 ℃ liquid
3. There must be no negative pressure in the pipeline
Teflon F-4 PTFE1. Boiling-resistant hydrochloric acid, sulfuric acid, nitric acid, aqua regia, concentrated alkali and various organic solutions
2. Strong abrasion resistance and poor bonding performance
3. There must be no negative pressure in the pipeline
Perchloroethylene propylene F-46(PTFE)1. On the basis of all functions of PTFE, the temperature of non-corrosive liquid can be increased within 140 degrees
2. Not resistant to fuming nitric acid, butyl lithium
3. There must be no negative pressure in the pipeline
Silicone fluoride liningTemperature resistance: 70 degrees, mainly high temperature. It can be used to measure hot water in heating systems, and is not resistant to corrosion.

Electromagnetic Flowmeter Electrode Material

MaterialCorrosion performance
316L electrodeApplication: domestic / industrial water, sewage
PH value: within 6/7/8
Not applicable: corrosive media such as hydrofluoric acid / hydrochloric acid / chlorine / iodine
HBApplication: certain concentration of hydrofluoric acid and other oxidizing acids and non-oxidizing hydrochloric acid, alkali solution with a concentration of not less than 70% sodium hydroxide.
PH value: within 5/6/7/8
Not applicable: Oxidizing acids such as nitric acid
HCApplication: corrosion resistance to oxidizing salts or environments containing other oxidants, especially to seawater. PH value is within: 6/7/8/9
Not applicable: hydrochloric acid, dilute sulfuric acid, phosphoric acid and other reducing acids and chlorides
TiApplication: chloride, hypochlorite, sea water, oxidizing acid.
PH value: within the range of 6/7/8/9/10
Not applicable: hydrochloric acid, sulfuric acid and other acidic media
TaApplication: concentrated hydrochloric acid, nitric acid, sulfuric acid and other acid liquids, including boiling hydrochloric acid and nitric acid.
PH value: within 3/4/5/6
Not applicable: alkali, hydrofluoric acid, fuming sulfuric acid

In practice , different options may be available to achieve the desired goal. To discuss the most suitable solutions to meet your specific needs and technical requirements , we would welcome your personal contact at any time.